Página 1

®For more detailed information, see your Vantage Vue Console manual.

Página 2 - Current Weather

9Press WIND to toggle between:• Wind Speed • Wind Direction (degrees)Press 2ND and UNITS to change unit of measure.There are four different units of

Página 3 - Moon Phase Icons

10Press RAIN to toggle between:• Rain Rate: current rate• Rain Day: rain accumulated since midnight• Rain Month: rain accumulated month-to-date• Rain

Página 4

11Press BAR to select: Barometric PressurePress 2ND and UNITS to change unit of measureThere are four units of measure for barometric pressure: 0.00

Página 5 - Setup Mode

12Press 2ND to select the second key function. The second key function is printed above the top keys and below the bottom keys.The icon will appear

Página 6

13Press 2ND and HEAT to: Display Heat IndexPress 2ND and DEW to: Display Dew PointPress 2ND and CHILL to: Display Wind ChillPress 2ND and UNITS to cha

Página 7

14Evapotranspiration measurements can only be accessed if the Vantage Vue Console is listening to a Vantage Pro2 Plus ISS or Vantage Pro2 with solar r

Página 8

15Press WXCEN for any Weather Variable to:• Toggle between multiple screens of weather information for each variable displayed in the Weather Center s

Página 9 - Humidity

16To view Graph Mode:1. Press a variable and then press GRAPH. The graph and the minimum and maximum readings for the selected weather variable displa

Página 10 - On the compass rose:

17To view highs and lows:1. Press HI/LOW. The time and date of the DAY HIGH for the currently selected weather variable, along with a graph showing th

Página 11 - Press RAIN to toggle between:

18Press TIME to toggle between:• Current Time & Date • Times of Sunrise & SunsetPress DONE to:• Accept an alarm setting. • Silence an a

Página 12 - Barometer

1NSWENESENWSWWINDamINSIDE OUTSIDERAIN RATECHILLin/hrF FFTime & Date, Sunrise/SunsetArrow shows which variable is selectedInside & OutsideTemp

Página 13 - Press 2nd and + or - to:

19To set an alarm:1. Press 2ND then ALARM to enter Alarm Mode. The alarm bell icon will appear on the screen. In each field, you will either see the

Página 14 - Dew Point

20When an alarm is triggered, you will hear an audible alarm:• Until conditions change (i.e., they rise above or fall below the alarm thresholds you h

Página 15 - (ET) (Optional)

21Enter or Change Alarm or CalibrationPress 2ND and SET to:Enter or change an alarm or calibration setting. Choose Alarm Mode or a weather variable:1.

Página 16

22To clear daily, monthly or yearly HIGH/LOW data:1. Press HI/LOW.2. Select the variable you wish to clear. 3. Press 2ND then CLEAR, holding CLEAR dow

Página 17 - To view Graph Mode:

23Press 2ND and UNITS to:Change the unit of measure for a selected variable.• All temperature-related readings (inside and outside temperature, wind c

Página 18 - Highs & Lows

24Press 2ND and SETUP to:Enter Setup Mode. Enter Setup Mode

Página 19 - Time/Date;

25Diagnostic ScreensTo Display the Console Diagnostic Screens: Press and hold TEMP then press HUM to display the Statistical Diagnostic Screen. Statis

Página 20 - Set Alarms

26DiagnosticScreensPress and hold TEMP then press HUM to display the Statistical Diagnostic Screen. Press 2ND and CHILL to toggle between the Statisti

Página 21 - Silence & Clear

27Vantage Vue® Console Quick Reference GuidePart Number: 7395.260Rev. B (1/6/12)©2012 Davis Instrument Corp. All Rights Reserved.Vantage Vue® is a tra

Página 22 - Alarm or Calibration

2IconsForecast IconsSee the Vantage Vue Console Manual for a list of all the forecast icons.Moon Phase IconsMoon phase icons are for Northern Hemisphe

Página 23 - To Clear All:

3IconsAlarm Bell — Appears when setting an alarm. Blinks on and off when an alarm is triggered.Graph — Indicates that graph mode is currently being di

Página 24 - Change Units

4Setup ModeTo enter Setup Mode: 1. Press and release 2ND and then press SETUP.2. Press DONE to advance or BAR to step back through setup screens: • TI

Página 25 - Enter Setup

5Setup Mode• ACTIVE TRANSMITTERS — Press < or > to select ID, use + or - to set to ON (to receive from that station) or OFF. Press GRAPH to chan

Página 26 - Diagnostic

6Setup Mode• WIND CUP (This option will only display if you have chose VP2 ISS or WIND in the ACTIVE TRANSMITTERS screen) — Press + or - to change win

Página 27

7Press LIGHT to toggle between:• Backlight on • Backlight offIf the console is running on AC power:• The backlight will remain on until you turn it of

Página 28

8Press TEMP to toggle between:• Outside Temperature • Inside TemperaturePress 2ND and UNITS to change unit of measure. There are four different