®C3 USER GUIDE®
C3 User Guide8
92. OverviewDescriptionThe C3 is a robust remote monitoring and control platform designed for deployment in rugged environments. The C3 platform consi
C3 User Guide101 - Battery status indicator2 - Radio status indicator3 - Power/user touch button4 - Output connector + indicator5 - Input connector +
111 - Ventilation slots2 - Information label3 - DIN rail mount4 - DIN rail mount clip toggle5 - UHF BNC antenna connector6 - xG SMA antenna connector7
C3 User Guide12&MFDUSJDBMTQFDJæDBUJPOTPower requirements• Connection via terminal block or 2.5 mm DC power connector• 60 V maximum on all power
13Weight• .PEVMFLHEFQFOEBOUVQPOSBEJPDPOæHVSBUJPO• Packed: 2.1 kg maximumMounting• Standard 32 mm DIN rail (Figure 2-3)• Locking cl
C3 User Guide14C3 Solar EnclosureComponents1 - Primary antenna whip2 - Mounting bracket3 - Bird deterrent4 - Primary antenna base5 - Secondary antenna
15781 - Solar panel thumb bolt2 - Module mounting rail3 - Note clip4 - Door Latch5 - Padlock loop6 - Mounting thumb bolt7 - Breather/drain8 - Bottom e
C3 User Guide16&MFDUSJDBMTQFDJæDBUJPOTPower• Nominal 14 W, 18 V crystalline PV panel• Internally routed 2-core solar power cable with 4-way plu
17Cable management• Single bottom entry M32 gland, suitable for electrical conduit up to 25 mm in diameter (Figure 4-8)• Two optional rear entry
Published byObservant Pty LtdABN: 21 104 666 882ACN: 104 666 882Level 1106 Victoria StFitzroy Victoria 3065AustraliaP: 1300 224 688 (+61 3 8415 0288 i
C3 User Guide182ABTxRxRS232/SDIRS485INPUTOUTPUT4334INPUTOUTPUT2211POWER1ABRS48512C3Figure 5. C3 installed in Solar Enclosure
193. InstallationPreparationLocationCare must be taken when selecting a site for the installation of a C3. It should have a clear aspect (down to the
C3 User Guide20antenna at a greater height above the ground if required. Greater pole diameters can be used if this is not a requirement.Pre-cablingIt
21• Un-fasten and tighten a hose-clamp around the mounting pole. • Mark the band approximately 15 – 20 mm past the worm-screw (Figure 6)• Cut three
C3 User Guide22Cable routing option 1: Bottom entry• Remove the Solar Enclosure from packaging and assemble to mount via tabs, the enclosure need
231 - Cable gland in place2 - Drill pilot mark3 - Pierce through cable gland123Figure 8. Optional rear entry cable glands3. Installation
C3 User Guide2412Figure 9. Installing enclosure on mounting bracketPrimary antenna mounting• Remove primary antenna base from packaging, remove slott
25123451 - Antenna base2 - Enclosure cross-section3 - Seal4 - Slotted nut (shoulder upward)5 - Antenna cableFigure 10. Primary antenna installationC3
C3 User Guide26123ABFigure 11. C3 module mounting
27Figure 12. Bird deterrent mounting3. Installation
1Contents1. General Information 5About this guide 5Warranty 52. Overview 9Description 9C3 10Components 10&MFDUSJDBMTQFDJæDBUJPOT .FDIBOJD
C3 User Guide28
294. AppendixA1. Electrical connectionsEquipment and power connections to the C3 module are made via 4-way 3.81 mm pluggable screw terminal blocks, wi
C3 User Guide30Label Function1Input 1Ground2Input 2GroundTable 1. Input1/2 connections (Figure 1-5)INPUT21Label Function3Input 3Ground4Input 4GroundTa
31Label Function3Output 3Ground4Output 4GroundTable 4. Output 3/4 connections (Figure 1-6)OUTPUT43RS232/SDI port• Nominal 12 V switched sensor power
C3 User Guide32RS485 ports (x2)• Nominal 12 V switched sensor power output (600 mA limit)• Standard 2-wire RS485 for multi-drop connections• Fault
33Power connections (x3)• Operational up to 60 V• 40 W peak total power draw across all inputs• 100 – 500 mW typical draw depending upon radio tech
C3 User Guide34RF antenna connections (x4)• $POOFDUJPOTBWBJMBCMFXJMMEFQFOEPODPOæHVSFESBEJPUFDIOPMPHZNJY• All connections are standard polari
35LED state Description4JOHMFHSFFOçBTIFWFSZTFDPOET• Battery healthy• No external power• Battery discharging%PVCMFHSFFOçBTIFWFSZTFDPOET• B
C3 User Guide36LED state DescriptionSolid green Input activeFlashing green (2 Hz) Input pulsingOff No input active, or user mode inactiveTable 13. Inp
37LED state Description.PNFOUBSZHSFFOçBTI Communications transmit.PNFOUBSZBNCFSçBTI Awaiting response.PNFOUBSZçBTIJOHSFE Communications response
C3 User Guide2Location 19Mounting posts 19Pre-cabling 20Unpacking 20C3 Solar Enclosure installation 20Mounting bracket 20Primary antenna mounting
C3 User Guide38 powered down until the button is pressed once again, or external power is presented• Note that activation of the button can be obs
3940°30°50°Figure 13. Solar panel angle setting4. Appendix
C3 User Guide40A4. Physical dimensions®50 – 90 mm (1.5 – 3” nominal) pipe diameter110 mm74 mm~455 mm328 mmUp to 420 mmFigure 21. Solar enclosure mount
4175mm164mm215mmC3POWER1ABRS485INPUT OUTPUT2AB TxRxINPUT RS232/SDIOUTPUT RS485221433411 2Figure 22. C3 dimensions 4. Appendix
C3 User Guide42A5. Device cabling guidelinesProtection• No cable (or part thereof) should be left exposed to the elements• The use of rigid electric
43Connections• Observant devices (V1, M2, L1) come pre-terminated with a waterproof 4-way in-line connector. Tails and extensions for these
C3 User Guide44Pulsed input• A pulsed switch or voltage output can be connected to a C3 input, for FYBNQMFBXBUFSçPXNFUFS• The frequency of th
4512 VDC240 VAC<600 mAOUTPUT21 Latch ReleaseOUTPUT21Figure 16. Control output examples4-20 mA analog input• Any loop powered 4 – 20
C3 User Guide46Voltage analog input• The C3 inputs can measure voltages up to 10 V• Higher voltage ranges can be measured by employing a divider res
47PowerRS485+RS485-Ground12 VDC<600 mAPowerRS485+RS485-GroundPowerRS485+RS485-GroundDevice 1 Device 2 Device n1ABRS485Figure 19. RS485 wiringPowerR
3A4. Physical dimensions 40A5. Device cabling guidelines 42Protection 42Distance 42Connections 43A6. Generic device wiring examples 43Switched inpu
C3 User Guide48A7. Supported sensing and control devicesObservant V1 cameraDescriptionThe V1 is a low-power, ruggedised, colour still image camera. It
49RedBlueYellowGreenABRS4851duleeowePOWER12121 - Male 4-way device connector (DTC)2 - Female 4-way device connectorFigure 22. V1 camera connection4. A
C3 User Guide50Figure 23. V1 mounting (rigid conduit)
51'JHVSF7NPVOUJOHçFYJCMFDPOEVJU4. Appendix
C3 User Guide52Figure 25. V1 mounting (direct)
53Observant M2 engine controllerDescriptionThe M2 is a fully featured engine monitoring and control interface. It communicates to the C3 via a 4-way c
C3 User Guide54EMERGENCY STOPSTART/STOPM2TMCommsBAPWR INRS485PM hrottleSparewnOKActiv–RedBlueYellowGreenRedBlueYellowGreenABRS4851duleeowePOWER12121 -
55Vaisala weather stationDescriptionThe Vaisala WXT520 is a multi-sensor weather station with no moving parts. Measurements of wind speed, direction,
C3 User Guide564FOTPSDPOåHVSBUJPO• 5IF895NVTUCFDPOæHVSFEWJBUIF7BJTBMBDPOæHVSBUJPOUPPMUPXPSL correctly with the Observant system• 8
57RedBlueYellowGreenABRS4851duleeowePOWER12211 - Male 4-way device connector (DTC)2 - Female 4-way device connectorFigure 27. Vaisala WXT520 electrica
C3 User Guide4A8. Other typical installation examples 77Electric pump control 77Mechanical engine monitoring and shutdown 80Equipment shutdown and
C3 User Guide58Senix ultrasonic level sensorDescriptionThe Senix ToughSonic TSPC ultrasonic level sensor can be used to measure water level in tanks,
59BrownYellowGreyBlueABRS4851oeuwowyPOWER12Figure 28. Senix TSPC connection4. Appendix
C3 User Guide60Linak Modbus enabled actuatorDescriptionThe Linak LA-35 and LA-36 series of linear actuators can be used to open, close or position irr
611 - Linak comms tail2 - Linak power tail3 - Fuse (10 A) 4 - Flexible conduit5 - C3-A power connector1ABRS485POWER2ABTxRxRS232/SDIRS48512NCBlackGreyB
C3 User Guide62Mono SMCDescriptionThe Mono SMC is an electric motor controller used in Mono Sun-Ray SRX solar water pumping systems. When connected to
63ON/OFFSPEEDSTATUS LIGHTSFLASHINGOFFDELAYDELAYHIGHTEMPSOLAR MOTOR CONTROLLERSOLAR PUMPING SYSTEMHAZARDOUS VOLTAGE INSIDE NOUSER SERVICABLE PARTSWARRA
C3 User Guide64Davis rain gaugeDescriptionThe Davis Rain Collector II is a typical example of a tipping bucket rain gauge with a 2-wire connection. Th
65OUTPUT21INPUT21RedGreenFigure 31. Davis rain gauge electrical connection4. Appendix
C3 User Guide66Pakton electric fence monitorDescriptionThe Pakton PTE0703 provides electrics fence voltage information over an RS232 serial link to th
67Electric Fencing SecurityTxRxRS232/SDI2ABRS485RedYellowBlueGreenHigh voltage fence connections Figure 32. Pakton PTE0703 electrical connection4. App
51. General InformationAbout this guideThis document provides information on the features, installation and typical usage of UIF$SFNPUFNPOJUPSJOH
C3 User Guide68.BDF9$JçPXNFUFSTDescription5IF.BDF9$JJTBEPQQMFSçPXNFUFSUIBUDBOCFDPOæHVSFEUPQSPWJEFJOTUBOUBOFPVTBOEUPUBMJTFEXBUFSçP
69Installation notes• The C3 is typically mounted separately from the Mace meter, but can exist on the same pole provided enough vertical room is
C3 User Guide70Sentek soil moisture probeDescriptionThe Sentek soil moisture probe measures soil electrical conductivity and moisture content. The pro
71RedBluePurpleBlackABRS4851euuadepcPOWER12Figure 34. Sentek probe electrical connection4. Appendix
C3 User Guide72Aquacheck soil moisture probeDescriptionThe Aquacheck soil moisture probe measures soil temperature and moisture content. The probes ar
73BrownBlackBlueGrn/YellowABRS4851neoPOWER12Figure 35. Aquacheck probe electrical connection4. Appendix
C3 User Guide74ADAM 4000 series IO modulesDescriptionObservant supports a range of ADAM 4000 IO expansion modules for cases where more digital inputs/
75Product codes• DTC: 6 m 4-way device cable (required for connection to C3)• DTE: 10 m 4-way device cable extension• DTB: 60 cm 4-way device cable
C3 User Guide76Other supported devicesObservant supports a further and continuously expanding range of serially connected devices. Please refer to the
77A8. Other typical installation examplesElectric pump controlDescriptionThe digital outputs of the C3 can be used to control contactors associated wi
C3 User Guide6required by Observant to evaluate and process any warranty claim.3. In order to obtain the above warranty service you will be asked to
C3 User Guide78OUTPUT21INPUT21A1A212A1A212A1A212A1A212STARTSTOPExisting12341 - Existing contactor2 - Start button3 - Stop button4 - 12 VDC/240 VAC rel
79OUTPUT21INPUT21A1A212A1A212Existing132RUNOFFAUTO1 - Existing contactor2 - Run switch3 - 12 VDC/240 VACFigure 38. Single input electric pump control4
C3 User Guide80Mechanical engine monitoring and shutdownDescriptionA combination of a C3 digital input and output can provide a simple method to add a
81OUTPUT21INPUT21GroundProtected ignitionFuel solenoid hold-in121 - Generic 12 VDC NC automotive relay2 - Engine with existing shutdown protectionFigu
C3 User Guide82Equipment shutdown and alarm triggersDescriptionThe C3 inputs can be used to sense conditions where equipment should be turn on/off, or
83OUTPUT21INPUT21NC or NOCommonFigure 40. Pressure switch electrical connectionOUTPUT21INPUT21NC or NOCommonFigure 41. Flow switch electrical connecti
C3 User Guide841 - Dry contact hall/inductive trigger4IBGUçZXIFFMXJUIGFSSPVTUSJHHFSOUTPUT21INPUT21NC or NOCommon12Figure 42. Shaft speed senso
85OUTPUT21INPUT21NC or NOCommonA1A212A1A212To mains or motor supplyFigure 44. Mains power supply monitoring electrical connection4. Appendix
C3 User Guide86RevisionsOBS-USR-M001-C3 User GuideR1: Initial release September 2012 (AJK)R2: February 2013 (AJK)• Added IP ratings, design life and
874. Appendix
7SUCH LOSS OR DAMAGE IS DIRECT, INDIRECT, CONSEQUENTIAL, SPECIAL, PUNITIVE OR EXEMPLARY (INCLUDING WITHOUT LIMITATION, LOSS OR DAMAGE, ANY LOSS OF PRO
Designed and made in Australiaobservant.com.au